Medical X-ray collimator Automatic x-ray collimator RF202

Medical X-ray collimator Automatic x-ray collimator RF202

Medical X-ray collimator Automatic x-ray collimator RF202

Short Description:

Features
Suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment
 The X-ray irradiation field is rectangular
Conform to relevant national and industry standards
High reliability and high cost performance
Using a single layer and two sets of lead leaves and a special internal protective structure to shield X-rays
The adjustment of the irradiation field is electric, the movement of the lead leaf is driven by a stepping motor, and the irradiation field is continuously adjustable
 Control the beam limiter through CAN bus communication or switch level, or manually control the beam limiter in front of you, and the LCD screen displays the status and parameters of the beam limiter
The visible light field adopts LED bulbs with higher brightness
The internal delay circuit can automatically turn off the light bulb after 30 seconds of light, and can manually turn off the light bulb during the light period to prolong the life of the light bulb and save energy
Convenient and reliable mechanical connection with X-ray tube, easy to adjust


Product Detail

Payment & Shipping Terms:

Product Tags

Technical parameters

Max Voltage 150KV
Maximum X-ray field  coverage  range 430mm×430mm (SID=100cm)
The average brightness of the light field >160 lux
Edge contrast ratio >4:1
Power supply requirement of projection lamp 24V AC/150W
Bright  X-ray  field  duration  for  Once 30S
Distance from Focal Spot of X-ray tube to the mount plane of collimator  SID  (mm)(optional) 60
Filtration(Inherent) 75kV 1mmAl
Filtration(Additional) The outer optional
Control  method Electric/ Manual
Drive motor Stepper Motor
Motor Control TTL  Level signals
Position detection Potentiometer
Input power AC24V/DC24V
(SID)Measuring tape optional
Center laser instructions optional
Dimension(mm)(W×L×H) 185×230×145
Weight(Kg) 7.2

Main technical parameters and indicators

X-ray leakage: <1mGy/h (150kV, 4mA)
The distance from the focus of the X-ray tube to the beam limiter mounting surface: 60mm (can be adjusted according to different tubes)
Maximum irradiation field: 43cmX43cm (SID=1m)
Minimum irradiation field: <5cmX5cm (SID=1m)
 Visible light field brightness: >140lux (SID=1m)
Light field consistency: <2%@SID
Inherent filtration: 1mmAl/75kV
Light field power input: 24VAC/50W or DC24V/1A
 Electrical control power input: 24VDC/2A
CAN bus protocol: CAN2.0A
 Dimensions: 186mm×230mm×145mm (length×width×height)
Weight: 7.2kg

Optional:
External additional filter
Special electrical interface
Special tube ball interface

Applications

This x-ray collimator is suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment


  • Previous:
  • Next:

  • Minimum Order Quantity: 1pc

    Price: Negotiation

    Packaging Details: 100pcs per carton or customized according to the quantity

    Delivery Time: 1~2 weeks according to the quantity

    Payment Terms: 100% T/T in advance or WESTERN UNION

    Supply Ability: 1000pcs/ month

  • Write your message here and send it to us